Description

Super Safety Valve Inconel 718

Product Description

Payment & Shipping Terms Supply Capacity
Unit Price: 200000.0 USD Production Capacity: 1set/month
Trade Term: FOB Packing: plywood
Payment Terms: L/C, T/T Delivery Date: 90days
Min. Order: 1 Set/Sets
Means of Transport: Ocean, Air, Land

Drill stem testing tools

Super Safety Valve

The Super Safety Valve is controlled by two hydraulic lines and contains a chemical injection port. It is designed to

close by spring force but has a nitrogen charge chamber to quicken the closing time.  This feature gives the valve the

ability to cut wireline and coiled tubing without the addition of balance line pressure.  The valve is held open by

maintaining hydraulic control pressure on the control line.  The nitrogen charge chamber and the balance line

chamber are the same chamber.  The nitrogen pressure acts directly on the operating piston and a floating check

valve keeps the nitrogen from escaping from the chamber into the balance line.  The check valve floats on the surface

of the water (or hydraulic fluid) as fluid is pumped into the chamber. When the fluid is removed, the floating check valve

sets down on the seat and seals the nitrogen charge in the chamber.

OPERATIONS GUIDELINES

Typically, the nitrogen charge chamber of the valve is charged with nitrogen to 1000 to 1500 psi. This charge is sufficient to cut 7/32 inch monoconductor cable, but it is not adequate to cut coiled tubing.  The valve can

be charged with nitrogen sufficient to cut coiled tubing, but this raises the required hold open pressure.  The tool is

capable of cutting 1.50 inch OD x 0.125 inch wall thickness coiled tubing by application of balance line pressure. The

hold open pressure varies with well conditions; however, it is roughly 2.5 times the nitrogen charge pressure.

All lines on the valve will hold 10000 psi, but a differential pressure between the control and balance line should not

exceed 3000 psi under normal circumstances (control line being higher).  This prevents the application of excessive

stress to the ball.  (10000 psi in the balance line with no control line pressure is within operational limits.)

Typically, the valve is run into the BOP where the valve controls the tubing area while the BOP pipe ram seals off the

annulus.

 

No Specification 8″
1 O.D. 203.2mm
2 Bore Diameter 76.5mm
3 Length 2855.5mm
4 Working pressure 103.5Mpa
5 Internal pressure strength 178.3Mpa
6 External pressure strength 257.8Mpa
7 Tensile strength 6299KN
8 Torque strength 137.6KN.m
9 Service H2S,NACE MR0175
10 Working temperature -29oC+204oC
11 Connection thread 5 3/4-4AS.B 5″-4ACME.B